Profibus PPO7 IO module object for frequency converter ABB ACS880.
This IO module are the receive and transmit areas for the profibus
protocol PPO7. See class ABB_ACS880_PPO7 for more information.
Connect the object to an object of class or subclass of
ABB_ACS880_1 with the IoConnect method.
Configuration
The class ABB_ACS880_PPO7_IoModule will automatically be
included when you configure an ABB_ACS880_Pb_Slave object in
the profibus configurator. See ABB_ACS880_Pb_Slave for more
information.
Example
The figure below displays the result of the Profibus configuration in
in the node hierarchy.
All the object for the Profibus slave, PPO7 and IO required to
communicate are displayed in the figure below.
Example Connected signal and channel
As the connection between individual signals and channels are predefined,
it is only required to make one Io connection between the ABB_ACS880_1 and
the IoModule object.
By opening a signal object it is possible to see the predefined connection.
The signal UserStatusSW1 is connected to the channel I_PZD6.
See also
RtBody attributes pwr_sClass_ABB_ACS880_PPO7_IoModule |
ChanIi |
I_ID |
|
Received ID message word from the converter |
ChanIi |
I_IND |
|
Received IND message word from the converter |
ChanIi |
I_VALUE |
|
Received Value message word from the converter |
ChanIi |
I_SW |
|
Received main status word from the converter
Parameter group 6 index 11. |
ChanAi |
I_ACT |
|
Received actual speed word from the converter
Parameter group 1 index 1. |
ChanAi |
I_PZD3_4 |
|
Received actual current word from the converter
Parameter group 1 index 7.
The parameter is defined in group 52 index 3 |
ChanAi |
I_PZD5 |
|
Received actual torque word from the converter
Parameter group 1 index 10.
The parameter is defined in group 52 index 5 |
ChanIi |
I_PZD6 |
|
Received user status 1 word from the converter
Parameter group 6 index 50.
The parameter is defined in group 52 index 6 |
ChanIi |
I_PZD7 |
|
Received warning message 1 word from the converter
Parameter group 4 index 6.
The parameter is defined in group 52 index 7 |
ChanIi |
I_PZD8 |
|
Received fault/tripped message 1 word from the converter
Parameter group 4 index 1.
The parameter is defined in group 52 index 8. |
ChanIi |
I_PZD9 |
|
Not connected channel that can be user defined.
The parameter is defined in group 52 index 9. |
ChanIi |
I_PZD10 |
|
Not connected channel that can be user defined.
The parameter is defined in group 52 index 10. |
ChanIi |
I_PZD11 |
|
Not connected channel that can be user defined.
The parameter is defined in group 52 index 11. |
ChanIi |
I_PZD12 |
|
Not connected channel that can be user defined.
The parameter is defined in group 52 index 12. |
ChanIo |
O_ID |
|
Transmitted ID word to the converter |
ChanIo |
O_IND |
|
Transmitted IND word to the converter |
ChanIo |
O_VALUE |
|
Transmitted Value word to the converter |
ChanIo |
O_CW |
|
Transmitted control word to the converter
Parameter group 6 index 1.
Parameter define in group 53 index 1. |
ChanAo |
O_REF |
|
Transmitted reference speed word to the converter
Parameter group 3 index 5.
Parameter define in group 53 index 2. |
ChanAo |
O_PZD3 |
|
Transmitted undefine word to the converter
Parameter define in group 53 index 3. |
ChanAo |
O_PZD4 |
|
Transmitted undefine word to the converter
Parameter define in group 53 index 4. |
ChanAo |
O_PZD5 |
|
Transmitted undefine word to the converter
Parameter define in group 53 index 5. |
ChanIo |
O_PZD6 |
|
Transmitted undefine word to the converter
Parameter define in group 53 index 6. |
ChanIo |
O_PZD7 |
|
Transmitted undefine word to the converter
Parameter define in group 53 index 7. |
ChanIo |
O_PZD8 |
|
Transmitted undefine word to the converter
Parameter define in group 53 index 8. |
ChanIo |
O_PZD9 |
|
Transmitted undefine word to the converter
Parameter define in group 53 index 9. |
ChanIo |
O_PZD10 |
|
Transmitted undefine word to the converter
Parameter define in group 53 index 10. |
ChanIo |
O_PZD11 |
|
Transmitted undefine word to the converter
Parameter define in group 53 index 11. |
ChanIo |
O_PZD12 |
|
Transmitted undefine word to the converter
Parameter define in group 53 index 12. |
Template Object |
I_ID.Description |
Parameter identification |
I_ID.ConversionOn |
1 |
I_ID.Representation |
2 |
I_IND.Description |
Array index |
I_IND.ConversionOn |
1 |
I_IND.Representation |
2 |
I_VALUE.Description |
Parameter value |
I_VALUE.ConversionOn |
1 |
I_VALUE.Representation |
1 |
I_SW.Description |
Status 16 bits from converter (fixed) |
I_SW.Identity |
52.1 (6.11) SW |
I_SW.ConversionOn |
1 |
I_SW.Representation |
3 |
I_ACT.Description |
Status word from converter (fixed) |
I_ACT.Identity |
52.1 (1.1) Act |
I_ACT.ConversionOn |
1 |
I_ACT.ScanInterval |
1 |
I_ACT.RawValRangeLow |
-2.000000e+04 |
I_ACT.RawValRangeHigh |
2.000000e+04 |
I_ACT.ChannelSigValRangeLow |
-2.000000e+04 |
I_ACT.ChannelSigValRangeHigh |
2.000000e+04 |
I_ACT.SensorPolyType |
1 |
I_ACT.SensorSigValRangeLow |
-2.000000e+04 |
I_ACT.SensorSigValRangeHigh |
2.000000e+04 |
I_ACT.ActValRangeLow |
-1.500000e+03 |
I_ACT.ActValRangeHigh |
1.500000e+03 |
I_ACT.Representation |
2 |
I_PZD3_4.Description |
Status word (32 bits) from converter |
I_PZD3_4.Identity |
52.3 and 4 (1.7) Current |
I_PZD3_4.ConversionOn |
1 |
I_PZD3_4.RawValRangeLow |
-3.000000e+06 |
I_PZD3_4.RawValRangeHigh |
3.000000e+06 |
I_PZD3_4.ChannelSigValRangeLow |
-3.000000e+06 |
I_PZD3_4.ChannelSigValRangeHigh |
3.000000e+06 |
I_PZD3_4.SensorPolyType |
1 |
I_PZD3_4.SensorSigValRangeLow |
-3.000000e+06 |
I_PZD3_4.SensorSigValRangeHigh |
3.000000e+06 |
I_PZD3_4.ActValRangeLow |
-3.000000e+04 |
I_PZD3_4.ActValRangeHigh |
3.000000e+04 |
I_PZD5.Description |
Status word from converter |
I_PZD5.Identity |
52.5 (1.10) Torque |
I_PZD5.ConversionOn |
1 |
I_PZD5.RawValRangeLow |
-3.276800e+04 |
I_PZD5.RawValRangeHigh |
3.276700e+04 |
I_PZD5.ChannelSigValRangeLow |
-3.276800e+04 |
I_PZD5.ChannelSigValRangeHigh |
3.276700e+04 |
I_PZD5.SensorPolyType |
1 |
I_PZD5.SensorSigValRangeLow |
-3.276800e+04 |
I_PZD5.SensorSigValRangeHigh |
3.276700e+04 |
I_PZD5.ActValRangeLow |
-3.276800e+02 |
I_PZD5.ActValRangeHigh |
3.276800e+02 |
I_PZD5.Representation |
2 |
I_PZD6.Description |
Status word or 16 bits from converter |
I_PZD6.Identity |
52.6 (6.50) USW1 |
I_PZD6.ConversionOn |
1 |
I_PZD6.Representation |
3 |
I_PZD7.Description |
Status word or 16 bits from converter |
I_PZD7.Identity |
52.7 (4.6) Warn1 |
I_PZD7.ConversionOn |
1 |
I_PZD7.Representation |
3 |
I_PZD8.Description |
Status word or 16 bits from converter |
I_PZD8.Identity |
52.8 (4.1) Fault1 |
I_PZD8.ConversionOn |
1 |
I_PZD8.Representation |
3 |
I_PZD9.Description |
Status word or 16 bits from converter |
I_PZD9.Identity |
52.9 free |
I_PZD9.ConversionOn |
1 |
I_PZD9.Representation |
3 |
I_PZD10.Description |
Status word or 16 bits from converter |
I_PZD10.Identity |
52.10 free |
I_PZD10.ConversionOn |
1 |
I_PZD10.Representation |
3 |
I_PZD11.Description |
Status word or 16 bits from converter |
I_PZD11.Identity |
52.11 free |
I_PZD11.Representation |
3 |
I_PZD12.Description |
Status word or 16 bits from converter |
I_PZD12.Identity |
52.12 free |
I_PZD12.Representation |
3 |
O_ID.Description |
Parameter identification |
O_ID.Representation |
3 |
O_IND.Description |
Array index |
O_IND.Representation |
3 |
O_VALUE.Description |
Parameter value |
O_VALUE.Representation |
1 |
O_CW.Description |
Control word to converter (fixed) |
O_CW.Identity |
53.1 (6.1) CW |
O_CW.Representation |
3 |
O_REF.Description |
Analog value word to converter (fixed) |
O_REF.Identity |
53.2 (3.5) Ref1 |
O_REF.OutPolyType |
1 |
O_REF.ActValRangeLow |
-1.500000e+03 |
O_REF.ActValRangeHigh |
1.500000e+03 |
O_REF.SensorSigValRangeLow |
-2.000000e+04 |
O_REF.SensorSigValRangeHigh |
2.000000e+04 |
O_REF.ChannelSigValRangeLow |
-2.000000e+04 |
O_REF.ChannelSigValRangeHigh |
2.000000e+04 |
O_REF.RawValRangeLow |
-2.000000e+04 |
O_REF.RawValRangeHigh |
2.000000e+04 |
O_REF.Representation |
2 |
O_PZD3.Description |
Analog value word to converter |
O_PZD3.Identity |
53.3 free |
O_PZD3.OutPolyType |
1 |
O_PZD3.ActValRangeHigh |
6.000000e+02 |
O_PZD3.SensorSigValRangeHigh |
6.000000e+04 |
O_PZD3.ChannelSigValRangeHigh |
6.000000e+04 |
O_PZD3.RawValRangeHigh |
6.000000e+04 |
O_PZD3.Representation |
2 |
O_PZD4.Description |
Analog value word to converter |
O_PZD4.Identity |
53.4 free |
O_PZD4.OutPolyType |
1 |
O_PZD4.ActValRangeHigh |
6.000000e+02 |
O_PZD4.SensorSigValRangeHigh |
6.000000e+04 |
O_PZD4.ChannelSigValRangeHigh |
6.000000e+04 |
O_PZD4.RawValRangeHigh |
6.000000e+04 |
O_PZD4.Representation |
2 |
O_PZD5.Description |
Analog value word to converter |
O_PZD5.Identity |
53.5 free |
O_PZD5.OutPolyType |
1 |
O_PZD5.ActValRangeLow |
-3.276800e+04 |
O_PZD5.ActValRangeHigh |
3.276700e+04 |
O_PZD5.SensorSigValRangeLow |
-3.276800e+04 |
O_PZD5.SensorSigValRangeHigh |
3.276700e+04 |
O_PZD5.ChannelSigValRangeLow |
-3.276800e+04 |
O_PZD5.ChannelSigValRangeHigh |
3.276700e+04 |
O_PZD5.RawValRangeLow |
-3.276800e+04 |
O_PZD5.RawValRangeHigh |
3.276700e+04 |
O_PZD5.Representation |
2 |
O_PZD6.Description |
Integer value word to converter |
O_PZD6.Identity |
53.6 free |
O_PZD6.Representation |
2 |
O_PZD7.Description |
Integer value word to converter |
O_PZD7.Identity |
53.7 free |
O_PZD7.Representation |
2 |
O_PZD8.Description |
Integer value word to converter |
O_PZD8.Identity |
53.8 free |
O_PZD8.Representation |
2 |
O_PZD9.Description |
Integer value word to converter |
O_PZD9.Identity |
53.9 free |
O_PZD9.Representation |
2 |
O_PZD10.Description |
Integer value word to converter |
O_PZD10.Identity |
53.10 free |
O_PZD10.Representation |
2 |
O_PZD11.Description |
Integer value word or bits to converter |
O_PZD11.Identity |
53.11 free |
O_PZD11.Representation |
3 |
O_PZD12.Description |
Integer value word or bits to converter |
O_PZD12.Identity |
53.12 free |
O_PZD12.Representation |
3 |