Class ABB_ACS880_1Sim
Redaktör je
Version 1.0
Modified 24-JUN-2013 11:11:20.51
Kod PlcTemplate
 Plc simulation object to profibus ABB_ACS80_1, powerlink ABB_ACS880_Epl_1
 or profinet ABB_ACS880_Pn_1.


Object Graph

 Connect the function object to an object of class or subclass of
 ABB_ACS880_1.

See also



RtBody attributes pwr_sClass_ABB_ACS880_1Sim
AttrRef PlcConnect   Reference to the simulated object.
Connect this object to ABB_ACS880_1 in plant hierarchy.
Boolean OpSimReplaceFan OpSimReplaceFan Simulate that the internal fan needs maintenance.
Boolean OpSimTripped OpSimTripped Simulate that the converter has tripped.
Boolean OpSimNotReady OpSimNotReady Simulate that the converter is not ready.
Boolean OpSimWarning OpSimNotReady Simulate that the converter has warning.
Boolean OpSimInhibit OpSimInhibit Simulate that the converter has warning.
Boolean OpSimNotRemote OpSimNotRemote Simulate that the converter is in internal local mode
i.e. button remote/local on the converters panel is
switched to local.
Boolean OpSimDi1 OpSimDi1 Simulate that the converter IO input Di1 is true.
Boolean OpSimDi2 OpSimDi2 Simulate that the converter IO input Di2 is true.
Boolean OpSimDi3 OpSimDi3 Simulate that the converter IO input Di3 is true.
Boolean OpSimDi4 OpSimDi4 Simulate that the converter IO input Di4 is true.
Boolean OpSimDi5 OpSimDi5 Simulate that the converter IO input Di5 is true.
Boolean OpSimDi6 OpSimDi6 Simulate that the converter IO input Di6 is true.
Boolean OpSimDiIL OpSimDiiL Simulate that the converter IO input DIIL is true.
Boolean OpSimSto OpSimSto Simulate that the converter IO input STO In1
and In2 is false, i.e. STO is activated.

DevBody attributes 
pwrs:Class-$PlcNode PlcNode  


GraphPlcNode
object_type 11
parameters[0] 0
parameters[1] 15
parameters[2] 0
parameters[3] 0
subwindows 1
subwindow_class[0] pwrb:Class-WindowPlc
graphmethod 0 (standard, individual attributes)
graphindex 0
default_mask[0] 0
default_mask[1] 0
segname_annotation 1
compmethod 58
compindex 0
tracemethod 0
traceindex 0
connectmethod 26
executeordermethod 2
objname ACS880_1Sim
graphname ACS880_1Sim


Template Object


Attributes detail


PlcConnect Intern
Klass Intern
Typ AttrRef
Flags
Kropp RtBody
  Reference to the simulated object.
  Connect this object to ABB_ACS880_1 in plant hierarchy.

OpSimReplaceFan Intern
Klass Intern
Typ Boolean
Flags State|Noedit
GraphName OpSimReplaceFan
Kropp RtBody
 Simulate that the internal fan needs maintenance.

OpSimTripped Intern
Klass Intern
Typ Boolean
Flags State|Noedit
GraphName OpSimTripped
Kropp RtBody
 Simulate that the converter has tripped.

OpSimNotReady Intern
Klass Intern
Typ Boolean
Flags State|Noedit
GraphName OpSimNotReady
Kropp RtBody
 Simulate that the converter is not ready.

OpSimWarning Intern
Klass Intern
Typ Boolean
Flags State|Noedit
GraphName OpSimNotReady
Kropp RtBody
 Simulate that the converter has warning.

OpSimInhibit Intern
Klass Intern
Typ Boolean
Flags State|Noedit
GraphName OpSimInhibit
Kropp RtBody
 Simulate that the converter has warning.

OpSimNotRemote Intern
Klass Intern
Typ Boolean
Flags State|Noedit
GraphName OpSimNotRemote
Kropp RtBody
 Simulate that the converter is in internal local mode
 i.e. button remote/local on the converters panel is
 switched to local.

OpSimDi1 Intern
Klass Intern
Typ Boolean
Flags State|Noedit
GraphName OpSimDi1
Kropp RtBody
 Simulate that the converter IO input Di1 is true.

OpSimDi2 Intern
Klass Intern
Typ Boolean
Flags State|Noedit
GraphName OpSimDi2
Kropp RtBody
 Simulate that the converter IO input Di2 is true.

OpSimDi3 Intern
Klass Intern
Typ Boolean
Flags State|Noedit
GraphName OpSimDi3
Kropp RtBody
 Simulate that the converter IO input Di3 is true.

OpSimDi4 Intern
Klass Intern
Typ Boolean
Flags State|Noedit
GraphName OpSimDi4
Kropp RtBody
 Simulate that the converter IO input Di4 is true.

OpSimDi5 Intern
Klass Intern
Typ Boolean
Flags State|Noedit
GraphName OpSimDi5
Kropp RtBody
 Simulate that the converter IO input Di5 is true.

OpSimDi6 Intern
Klass Intern
Typ Boolean
Flags State|Noedit
GraphName OpSimDi6
Kropp RtBody
 Simulate that the converter IO input Di6 is true.

OpSimDiIL Intern
Klass Intern
Typ Boolean
Flags State|Noedit
GraphName OpSimDiiL
Kropp RtBody
 Simulate that the converter IO input DIIL is true.

OpSimSto Intern
Klass Intern
Typ Boolean
Flags State|Noedit
GraphName OpSimSto
Kropp RtBody
 Simulate that the converter IO input STO In1
 and In2 is false, i.e. STO is activated.

PlcNode Buffer
Klass Buffer
Typ pwrs:Class-$PlcNode
Flags
Kropp DevBody