Class ABB_ACS880_1Sim![]() |
||
---|---|---|
Redaktör | je | |
Version | 1.0 | |
Modified | 24-JUN-2013 11:11:20.51 | |
Kod | PlcTemplate |
Plc simulation object to profibus ABB_ACS80_1, powerlink ABB_ACS880_Epl_1 or profinet ABB_ACS880_Pn_1.
Object Graph
Connect the function object to an object of class or subclass of ABB_ACS880_1.See also
RtBody attributes pwr_sClass_ABB_ACS880_1Sim | |||
---|---|---|---|
AttrRef | PlcConnect | Reference to the simulated object. Connect this object to ABB_ACS880_1 in plant hierarchy. |
|
Boolean | OpSimReplaceFan | OpSimReplaceFan | Simulate that the internal fan needs maintenance. |
Boolean | OpSimTripped | OpSimTripped | Simulate that the converter has tripped. |
Boolean | OpSimNotReady | OpSimNotReady | Simulate that the converter is not ready. |
Boolean | OpSimWarning | OpSimNotReady | Simulate that the converter has warning. |
Boolean | OpSimInhibit | OpSimInhibit | Simulate that the converter has warning. |
Boolean | OpSimNotRemote | OpSimNotRemote | Simulate that the converter is in internal local mode i.e. button remote/local on the converters panel is switched to local. |
Boolean | OpSimDi1 | OpSimDi1 | Simulate that the converter IO input Di1 is true. |
Boolean | OpSimDi2 | OpSimDi2 | Simulate that the converter IO input Di2 is true. |
Boolean | OpSimDi3 | OpSimDi3 | Simulate that the converter IO input Di3 is true. |
Boolean | OpSimDi4 | OpSimDi4 | Simulate that the converter IO input Di4 is true. |
Boolean | OpSimDi5 | OpSimDi5 | Simulate that the converter IO input Di5 is true. |
Boolean | OpSimDi6 | OpSimDi6 | Simulate that the converter IO input Di6 is true. |
Boolean | OpSimDiIL | OpSimDiiL | Simulate that the converter IO input DIIL is true. |
Boolean | OpSimSto | OpSimSto | Simulate that the converter IO input STO In1 and In2 is false, i.e. STO is activated. |
DevBody attributes | |||
---|---|---|---|
pwrs:Class-$PlcNode | PlcNode |
GraphPlcNode | |
---|---|
object_type | 11 |
parameters[0] | 0 |
parameters[1] | 15 |
parameters[2] | 0 |
parameters[3] | 0 |
subwindows | 1 |
subwindow_class[0] | pwrb:Class-WindowPlc |
graphmethod | 0 (standard, individual attributes) |
graphindex | 0 |
default_mask[0] | 0 |
default_mask[1] | 0 |
segname_annotation | 1 |
compmethod | 58 |
compindex | 0 |
tracemethod | 0 |
traceindex | 0 |
connectmethod | 26 |
executeordermethod | 2 |
objname | ACS880_1Sim |
graphname | ACS880_1Sim |
Template Object |
---|
PlcConnect Intern | ||
---|---|---|
Klass | Intern | |
Typ | AttrRef | |
Flags | ||
Kropp | RtBody |
Reference to the simulated object. Connect this object to ABB_ACS880_1 in plant hierarchy.
OpSimReplaceFan Intern | ||
---|---|---|
Klass | Intern | |
Typ | Boolean | |
Flags | State|Noedit | |
GraphName | OpSimReplaceFan | |
Kropp | RtBody |
Simulate that the internal fan needs maintenance.
OpSimTripped Intern | ||
---|---|---|
Klass | Intern | |
Typ | Boolean | |
Flags | State|Noedit | |
GraphName | OpSimTripped | |
Kropp | RtBody |
Simulate that the converter has tripped.
OpSimNotReady Intern | ||
---|---|---|
Klass | Intern | |
Typ | Boolean | |
Flags | State|Noedit | |
GraphName | OpSimNotReady | |
Kropp | RtBody |
Simulate that the converter is not ready.
OpSimWarning Intern | ||
---|---|---|
Klass | Intern | |
Typ | Boolean | |
Flags | State|Noedit | |
GraphName | OpSimNotReady | |
Kropp | RtBody |
Simulate that the converter has warning.
OpSimInhibit Intern | ||
---|---|---|
Klass | Intern | |
Typ | Boolean | |
Flags | State|Noedit | |
GraphName | OpSimInhibit | |
Kropp | RtBody |
Simulate that the converter has warning.
OpSimNotRemote Intern | ||
---|---|---|
Klass | Intern | |
Typ | Boolean | |
Flags | State|Noedit | |
GraphName | OpSimNotRemote | |
Kropp | RtBody |
Simulate that the converter is in internal local mode i.e. button remote/local on the converters panel is switched to local.
OpSimDi1 Intern | ||
---|---|---|
Klass | Intern | |
Typ | Boolean | |
Flags | State|Noedit | |
GraphName | OpSimDi1 | |
Kropp | RtBody |
Simulate that the converter IO input Di1 is true.
OpSimDi2 Intern | ||
---|---|---|
Klass | Intern | |
Typ | Boolean | |
Flags | State|Noedit | |
GraphName | OpSimDi2 | |
Kropp | RtBody |
Simulate that the converter IO input Di2 is true.
OpSimDi3 Intern | ||
---|---|---|
Klass | Intern | |
Typ | Boolean | |
Flags | State|Noedit | |
GraphName | OpSimDi3 | |
Kropp | RtBody |
Simulate that the converter IO input Di3 is true.
OpSimDi4 Intern | ||
---|---|---|
Klass | Intern | |
Typ | Boolean | |
Flags | State|Noedit | |
GraphName | OpSimDi4 | |
Kropp | RtBody |
Simulate that the converter IO input Di4 is true.
OpSimDi5 Intern | ||
---|---|---|
Klass | Intern | |
Typ | Boolean | |
Flags | State|Noedit | |
GraphName | OpSimDi5 | |
Kropp | RtBody |
Simulate that the converter IO input Di5 is true.
OpSimDi6 Intern | ||
---|---|---|
Klass | Intern | |
Typ | Boolean | |
Flags | State|Noedit | |
GraphName | OpSimDi6 | |
Kropp | RtBody |
Simulate that the converter IO input Di6 is true.
OpSimDiIL Intern | ||
---|---|---|
Klass | Intern | |
Typ | Boolean | |
Flags | State|Noedit | |
GraphName | OpSimDiiL | |
Kropp | RtBody |
Simulate that the converter IO input DIIL is true.
OpSimSto Intern | ||
---|---|---|
Klass | Intern | |
Typ | Boolean | |
Flags | State|Noedit | |
GraphName | OpSimSto | |
Kropp | RtBody |
Simulate that the converter IO input STO In1 and In2 is false, i.e. STO is activated.
PlcNode Buffer | ||
---|---|---|
Klass | Buffer | |
Typ | pwrs:Class-$PlcNode | |
Flags | ||
Kropp | DevBody |